    JIS G3461 STB410 BOILER AND HEAT EXCHANGER TUBES
    X
    JIS G3461 STB410 BOILER AND HEAT EXCHANGER TUBES

    EN 10216-2 P195GH SEAMLESS STEEL TUBES

    Categories:

    Contact Now

    EN 10216-2 P195GH Seamless Steel Tubes 

    Standard:EN 10216-2 Seamless steel tubes for pressure purposes —Technical delivery conditions Part 2: Non-alloy and alloy steel tubes with specified elevated temperature properties EN 10216-2 P195GH Seamless steel tubes for pressure purposes   EN 10216-2 P195GH Seamless steel tubes Quick Details Manufacture:Seamless process Wall thickness(WT): 2.1mm——20 mm. Outer diameter (OD): 21 mm——509mm Length: 6M or specified length as required. Ends: Plain End, Beveled End, Treaded   The steel name of non-alloy steel grades (1)The capital letter P for pressure purposes; (2)The symbols GH for elevated temperature.   EN 10216-2 P195GH Seamless steel tubes shall be supplied in the relevant heat treatment conditions as specified in Table 1.

    Steel grade

    Heat treatment a Austenizing Tempering

    Steel name

    Steel number Temperature °C Cooling Medium Temperature °C

    Cooling medium

    P195GH 1.0348 +N b 880 to 940 Air

    a  +N = Normalising, +NT = Normalising + Tempering, +QT = Quenching + Tempering (air or liquid), +I = Isothermal Annealing. b  Normalising includes Normalising Forming.
      Chemical composition of EN 10216-2 P195GH

    Steel grade

    Steel number C Si Mn P max S max Cr Mo Ni
    195GH 1.0348 ≤ 0,13 ≤ 0,35 ≤ 0,70 0,025 0,020 ≤ 0,30 ≤ 0,08

    ≤ 0,30

    Al tot

    Cu Nb Timax V Cr+Cu+Mo+Ni Others
    ≥ 0,020 ≤ 0,30 c ≤ 0,010 0,040 ≤ 0,02 ≤ 0,70

      Mechanical properties of EN 10216-2 P195GH

    Steel grade

    Upper yield strength or proof strength R eH or Rp 0,2 for Wall Thickness T min.

    Tensile Strength Rm

    Steel name

    Steel number

    T ≤ 16 16 < T ≤ 40 40 < T ≤ 60 60 < T ≤ 100
    MPa * MPa * MPa * MPa *

    MPa *

    P195GH 1.0348 195

    320 to 440

    Note:l = longitudinal t = transverse   Dimensions tolerances of EN 10216-2 on outside diameter and wall thicknes

    Outside Diameter D mm

    Tolerances on D Tolerances on T for a T/D ratio
    ≤ 0,025 > 0,025 ≤ 0,050 > 0,050 ≤ 0,10

    > 0,10

    D ≤ 219,1

    ± 1% or ± 0.5mm whichever is the greater ± 12,5% or ± 0.4mm whichever is the greater
    D > 219,1 ± 20% ± 15% ± 12,5%

    ± 10%

    For outside diameters D ≥ 355,6 mm it is permitted to exceed the upper wall thickness locally by a further 5% of the wall thickness T
      Tolerances on inside diameter and wall thickness
    Tolerances on inside diameter

    Tolerances on T for a T/d ratio

    d

    d min ≤ 0,03 > 0,03 ≤ 0,06 > 0,06 ≤ 0,12

    > 0,12

    ± 1% or ± 2 mm whichever is the greater (+ 2% ,0)or (+ 4 mm,0) whichever is the greater ± 20% ± 15% ± 12,5%

    ± 10%

     For outside diameters D ≥ 355,6 mm it is permitted to exceed the upper wall thickness locally by a further 5% of the wall thickness T

      Tolerances on outside diameter and minimum wall thickness
    Outside diameter D mm

    Tolerances on D

    Tolerances on T min for a T min /D ratio

    ≤ 0,02 > 0,02 ≤ 0,04 > 0,04 ≤ 0,09

    > 0,09

    D ≤ 219,1

    ± 1% or ± 0.5mm whichever is the greater (+ 28%,0) or (+ 0.8 mm,0) whichever is the greater
    D > 219,1 + 50% 0 + 35% 0 + 28% 0

    + 22% 0

    For outside diameters D ≥ 355,6 mm it is permitted to exceed the upper wall thickness locally by a further 5% of the wall thickness T

      Tolerances on inside diameter and minimum wall thickness

    Tolerances on inside diameter

    Tolerances on T min for a T min /d ratio

    d

    d min ≤ 0,05 > 0,05 ≤ 0,1 > 0,1

    ± 1% or ± 2 mm whichever is the greater

    (+2%,0) or (+ 4 mm,0) whichever is the greater + 35% 0 + 28% 0

    + 22% 0

    For outside diameters D ≥ 355,6 mm it is permitted to exceed the upper wall thickness locally by a further 5% of the wall thickness T

      Tolerances on exact lengths Dimension in mm

    Length L

    Tolerance on exact length

    L ≤ 6000

    +10 0
    6000 < L ≤ 12 000

    +15 0

    L > 12 000

    + by agreement 0

      TESTINGS (1)Chemical analysis (2)Tensile test(Tensile test at room temperature, Tensile test at elevated temperature) (3)Flattening test (4)Ring tensile test (5)Drift expanding test (6)Ring expanding test (7)Impact test (8)Leak tightness test(Hydrostatic test,  Electromagnetic test) (9)Dimensional inspection (10) Visual examination (11) Non-destructive testing

    Request Inquery

    Request a Quote

    Contact Us

  • North Steel (Sydney) Group Co., Ltd
  • +61 478727799info@north-steel.com
  • Room 604, No. 2, Beichen Building, Beichen District, Tianjin, China.
  • +61 478727799  +61 434518549

    Head Office

    Room 604, No. 2 Beichen Building, Beichen District, Tianjin, China.

    Australian Office

    72/208 Parramatta Rd, Homebush, NSW 2140, Australia.

    Copyright © 2025 North Steel (Sydney) Group Co., Ltd.  All Rights Reserved.

    Contact Us

    Request Inquery